Release AHU Design v. 3.10.0 (2023-11-30)
Release AHU Design v. 3.10.0 (2023-11-30)
NEWS: GLOBAL PX LP Mirror
NEWS: Added possibility to add heating coil water/electrical on exhaust air both in duct and cased.
APPLICATION / GUI / Calculation
- News: New technical version v.36
- Bug-fix: Warning when changing unit size
- News: DLL update Roen Est DLL (coils for GLOBAL and ESENSA)
- News: New Sound data model for GLOBAL PX LP (Release date, 5th of December)
- News: Energy printout - Include comparison without energy recovery
- Bug-fix: Fixed issue with heating coils after RX/HC at other Operating Setup
GOLD, SILVER & COMPACT AIR
- Improvement: Added possibility to select dehumidification-sensor in room
- Improvement: Added extra filterkit for afterfilter (TCFB) for size 100-120
- Improvement: Added possibility to have complete valve kit with ethanol as liquid
- Improvement: Added TBKA on outdoor when connection is upwards
- Improvement: Added possibility to select and calculate electrical coil on multi-function part
- Improvement: Improved management of coils configurations, to secure correct wiring diagrams
- Improvement: Added possibility to order inspection window and internal lights on RX unit for RX/HC
- Improvement: Pulse counter possible to select also in menu External Operation Control (Control system)
- Improvement: TBXZ188 and TBXZ189 is also selectable for GOLD
- Improvement: Added short description on all duct and cased components:
- Improvement: Multiple languages corrections
- Bug-fix: Corrected rotor description in flowchart
- Bug-fix: Corrected wiring diagram for SUSA in combination with I/O module
- Bug-fix: Corrected wiring diagram when smoke detector and pressure guard, both was selected
- Bug-fix: Corrected handling for coils and transitions for TOP unit size 25-30 (TBKA, TBLA and TBKC)
- Bug-fix: Corrected TBLF and transitions on TOP units size 14-30
- Bug-fix: Corrected electrical connections for GOLD RX/HC in technical printout
- Bug-fix: Corrected damper set of duct recirculation for GOLD RX/HC size 11/12
GLOBAL/ESENSA
- Improvement: Added possibility to select prefilter in all GLOBAL SD coils (picture?)
- Improvement: Possibility to add two coils of the same type in GLOBAL SD
- Improvement: Changed purge sector warning to information message
- Removed condensate pump on LP OUT
- Bug-fix: Corrected dimensions for weather hoods for GLOBAL SD
- Bug-fix: Default value of analog sensor (K2) corrected
GOLD NA
- Improvement: Added possibility to place empty ACLA on exhaust air