You might want to visit our global site:

Release AHU Design v. 4.2.0 (2024-09-26)

Transport packages phase 2 for GOLD AND SILVER RX, PX, CX, SD, H/C

Transport packages phase 2 is including a new drawing with accessories transport packages for casing accessories.

Unit transport packages

Accessories transport packages

 

 

Transport packages phase 1 for GLOBAL RX, PX, RX TOP and PX TOP

Transport packages for GLOBAL is now available and are divided into 3 different drawings.

First drawing is the selected unit with dimensions, second drawing showing ducts and roof component with dimensions and the third drawing is the transport packages including pallets.

 

In the next phase, transport packages will include remaining product range for GLOBAL and also full range for ESENSA.

Unit with dimensions​

Duct and roof components with dimensions

Transport packages including pallets

 

 

CASA Genius R3, R4C, R5, R7, R9, R15, W3, and W4 available for all European market.
 

Swegon CASA R3 Genius

CASA R4-C

Swegon CASA R5 Genius

Swegon CASA R7 Genius

CASA Genius R3

CASA Genius R4C

CASA Genius R5

CASA Genius R7

Swegon CASA R9 Genius

Swegon CASA R15 Genius

Swegon CASA W4xs Genius

Swegon CASA W4xs Genius

CASA Genius R9

CASA Genius R15

CASA Genius W3 xs

CASA Genius W4 xs

 

Abbreviation-list Printout

The new printout in AHU Design covering explanation of abbreviations and classifications used​

  • Available for GOLD and SILVER C ​

 

Technical version

New technical version 40

 

 

APPLICATION / GUI / Calculation 

Bug-fix: Fixed wrong scale in CASA Fan Diagrams

Improvement: Climate data adjustment for Calgary

Bug-fix: Fix coils for Global SD - RECalc

Improvement: Security improvements

Improvement: Technical Version visible under Project Setup -> Version Info

Improvement: Improved usability for Configuration error popup dialogs.

 

KVÄNUM

Eurovent technical update: GOLD/SILVER C with rotary heat exchanger type MTE has increased rotor pressure drop and reduced fan power consumption. The temperature efficiency is not affected at all and the SFPv is only slightly affected.

Eurovent technical update: The calculation of the Eurovent Summer/Winter Energy Efficiency class for Gold and Silver C has been corrected in line with Eurovent Certification requirements.

Improvement: Wiring diagram and Control system has been updated for DX-coils when supplier is Other Manufacturer. (25118)

Improvement: Wiring diagram for CX and SDCX. (27434)

Improvement: Add possibility to choose circulation pump for heating in a combi coil. (28568)

Bug-fix: Indication of filter is now available in control system for TCFB.(26745)

Bug-fix: X-zone combi detail correction in printouts. (27133)

Bug-fix: Corrected distance measurement between bottom beam for GOLD/SILVER C SD CX size 11 (27339)

Bug-fix: Showing wrong airflow connection in flowchart for left supply air on GOLD PX defrost (27510)

Bug-fix: Corrected possibility to add damper before electrical coil on outdoor airflow for GOLD/SILVER C SD (27654)

Bug-fix: Corrected Defrost variant (Recirculation with electrical coil) when duct dampers component is added to GOLD RX/HC (27719)

Bug-fix: Correction of weight for above configuration(27719). (27902)

Bug-fix: Correction of power supply in wiring diagram when electrical timer is added (27823)

Bug-fix: Article number for stored units is now corrected. (27990)

Bug-fix: Electrical coil missing in wiring diagram when selecting combi coil. (28338)

Bug-fix: SILVER C Fan designation is corrected on technical printout. (28468)

Bug-fix: Correction of connection back on TCGA for exhaust airflow (28677)

 

GEMBLOUX

Eurovent technical update: The calculation of the Eurovent Summer/Winter Energy Efficiency class for GLOBAL has been corrected in line with Eurovent Certification requirements.

Improvement: Possibility to select empty casing on ECA component. (26940)

Improvement: Possibility to add EBA coil on Esensa Flex (28238)

Improvement: Graphical update on roof holder for GLOBAL LP size 16 and 18. (27643)

Improvement: Improved warning on post heating for GLOBAL and ESENSA. (27979)

Bug-fix: Damper article for ESENSA flex size 5 has now been correct (27642)

Bug-fix: Unit power supply missing on ESENSA Flex. (27658)

 

NORTH AMERICA

Improvement: Selection and naming of smoke detectors for SD single flow. (25629)

Improvement: Electrical pre-heater (ACLE) added for SD. (26856)

Improvement: Bottom connection part (ACBC) added for size 50/60 & 70/80. (27146)

Improvement: Adjusted electrical data of units, and electrical heater. (27546)

Improvement: Smoke detector length (articles CA100581/582/583) automatically fixed to unit size. (27814)

Bug-fix: Missing temperature sensor BT7 in flowchart. (26838)

Bug-fix: Incorrect indication of heating-cooling sequence in order configuration (ACLK & ACEK). (26919)

Bug-fix: Missing voltage order configuration of SD with 208V transformer. (27385)

Bug-fix: Incorrect order configuration of empty casings (ACLE, ACLA, ACKA, ACLK, ACEK). (27453)

Bug-fix: Swapped order configuration of level for accessories. I.e. accessories placed down was indicated upper level, and vice versa. (28213)

Bug-fix: Order configuration of roof quantity (ABTB). (28922)

 

RESIDENTIAL (KAARINA)

 

Improvement: Multiple fixes for graphics

Improvement: Country specific article numbers

Improvement: Extra filters available on design page

Improvement: Possibility to print SFPe value (partly dirty filters) in technical printout.

Bug-fix: Surrounding sound corrections for all unit size in Technical Printout.

Correction: Heating recovery efficiency is now calculated in same manner as all other Units in AHU Design